AC Power Lockout Panels

AC Power Lockout Panels

 

AC Lockout Panels from AC General provides a simple, safe, and effective way to comply with OSHA regulations for de-energizing your factory test equipment for maintenance. 

Our panels provides positive lockout of AC power from an Equipment Rack. The panel can serve as a primary power entry panel to your test rack. Other features may include mating cables or connectors, multi-source power inputs, and network/signal IO ports.

Using our lockout panel is simple. Disconnect your facility power source, close the Hinged Door, and secure it with standard Electrician’s safety locks. Quick, safe, and reliable OSHA compliance.

 

Scroll down to explore common lockout panels and search for details including amperage, connectors, and more.

Need More Information?

Interested in learning how AC General can custom design a Lockout Panel specifically to fit your needs?
The easiest way to reach us is through our online contact form
.

Features

  • Designed for 20A, 30A, 60A, and 100A electrical service
  • Thick Aluminum panel won’t flex or bend under heavy power cord connections
  • Connector mounting holes will accept many common NEMA or IEC 60309 power connectors
  • Hinged door and steel hasp will provide secure and visible lockout
  • Single and multi-input power source panels are designed for most equipment rack power sources
  • Can also be used as general-purpose AC power input panel

Common AC Lockout Panels

The table shown below contains a partial list of common AC Power Lockout Panels.

Use the Search box to parse on Amperage (e.g. “60 Amps”), NEMA connector (e.g. “L-21-20P”), or other related terms.

In the Image column, click on a panel image to see a larger view.

Click on this link to see a list of common NEMA connectors

Many of our AC Lockout Panels have been tailored or adapted to meet unique Customer requirements and may not be shown. Contact AC General to discuss your requirements.

 

Part NumberDescriptionDetails
P/N 020-029Three-Phase AC Lockout Panel, 20 Amp or 30 Amp, Three-Phase

Designed for (1) NEMA 20 Amp, 30 Amp, or 20 Amp/400 Hertz Locking Flanged Inlet connector:


  • L14-20P, L15-20P, L16-20P, L17-20P, L21-20P, L22-20P, L23-20P

  • L14-30P, L15-30P, L16-30P, L17-30P, L21-30P, L22-30P, L23-30P

  • 400 Hz, Hubbell 45985CL (non-NEMA)


P/N 020-030AC Lockout Panel, Dual Inputs, 20 Amp or 30 Amp, Three-Phase

Designed for (2) NEMA 20 Amp, 30 Amp, or 20 Amp/400 Hertz Locking Flanged Inlet connectors:


  • L14-20P, L15-20P, L16-20P, L17-20P, L21-20P, L22-20P, L23-20P

  • L14-30P, L15-30P, L16-30P, L17-30P, L21-30P, L22-30P, L23-30P

  • 400 Hz, Hubbell 45985CL (non-NEMA)


P/N 020-032AC Lockout Panel, 20 Amp or 30 Amp, Single Phase

Designed for (1) NEMA 20 Amp or 30 Amp Locking Flanged Inlet connector:


  • L5-20P, L6-20P, L7-20P

  • L5-30P, L6-30P, L7-30P


P/N 020-060AC Lockout Panel, 60 Amp, Three-Phase

Designed for (1) Three-Phase 60Amp Flanged Mount HUBBLELOCK Connector:


  • Hubbell 26522


P/N 020-065AC Lockout Panel, 60 Amp, Three-Phase, with optional I/O Panel Insert

Designed for (1) Three-Phase 60Amp Flanged Mount HUBBLELOCK Connector:



  • Hubbell 26522 (non-NEMA)

  • Panel Insert can be customized to accomodate various connector cut-outs (insert sold seperately, contact AC General)



P/N 020-084AC Lockout Panel for (1) Single Input and (1) Single Output, 30 Amp, Three-Phase

Lockout panel includes input and output power cables:


  • 30 Amp power input cable, P/N 400-053-06 ( 6 feet)

  • 30 Amp power output cable, P/N 400-077-06 (6 feet)


P/N 020-099AC Lockout Panel, IEC Pin & Sleeve, 100 Amp (with connectors)

Includes IEC 60309-1/60309-2 Compliant Inlet and Mating Connector:


  • HBL5100B9W 100 Amp 120/208 VAC Three-Phase inlet (Included) plus Mating connector, HBL5100C7W (Included)



P/N 020-100AC Lockout Panel, Dual Input, 20 Amp or 30 Amp Three-Phase and 20 Amp or 30 Amp Single Phase

Designed to accommodate both a single phase and Three-Phase Locking Flanged Inlet connectors:


  • Three-Phase inlet sizes same as P/N 020-029 (Hole Dia: 2.25")

  • Single phase inlet sizes same as P/N 020-032 (Hole Dia: 2.125")


P/N 020-106AC Lockout Panel, IEC Pin & Sleeve, 60 Amp

Hole and bracket design is compliant to IEC 60309-1/60309-2 Connector mounting.


  • Panel hole designed to accept 2P/3W, 3P/4W, and 4P/5W, 60 Amp Flanged Pin & Sleeve Inlets:

  • The mounting bracket will accept any 60A IEC 60309 compliant INLET connector (Hubbell, Leviton, Mennekes, Eaton, ElecDirect)/li>
  • Removable bracket facilitates connector mounting

  • Flanged inlet and mating connector must be ordered separately


020-179AC Lockout Panel, IEC Pin & Sleeve, 100 Amp

Hole and bracket design is compliant to IEC 60309-1/60309-2 Connector mounting.


  • Panel hole designed to accept 2P/3W, 3P/4W, and 4P/5W, 60 Amp Flanged Pin & Sleeve Inlets:

  • The mounting bracket will accept any 100A IEC 60309 compliant INLET connector (Hubbell, Leviton, Mennekes, Eaton, ElecDirect)/li>
  • Removable bracket facilitates connector mounting

  • Flanged inlet and mating connector must be ordered separately


P/N 020-115AC Lockout Panel, Dual Input, 120/208 VAC Three-Phase 60 Hz and 120/208 VAC Three-Phase 400 Hz

Designed for two Locking Flanged Inlet connectors rated at 120/208VAC service. Panel is marked with service ratings:


  • J1 will accept NEMA L21-20P or L21-30P

  • J2 will accept 400 Hz, Hubbell 45985CL (non-NEMA)

  • Connectors not included


P/N 020-120AC Output Lockout Panel, Three-Phase 120/208 VAC 20A 400Hz

Panel includes pre-mounted 20 Amp Three-Phase 400 Hertz Locking Receptacle with 6 foot power cord that connects to a 400 Hz power source. Designed to lockout an output power source.


  • Output receptacle (J20): 400 Hz, Hubbell 45985CL (non-NEMA). Mating connector, Hubbell 45915 (not provided)

  • Plug: 400 Hz, Hubbell 45915